The AOS124 signal converter allows a LIGI light curtain with OSE output to be adapted to control panel that do not have this technology.
The OSE signal is converted into a relay signal (potential-free).
Advantages
1 input for 1 OSE device
1 relay output + test input
NO or NC relay output
LED indicators for input and output status
Category 2 device, compliant
with ISO13849-1 standard
Technical specifications
Power supply 19…35 VCC o 19…30 VCA
Input 1x OSE signal
Output Relay/TEST inputs
Light Indicator Yellow LED
Security Cat. 2, ISO 13849-1
Protection degree IP65


Control board for resistive edges: equipped with two channels, ensures continuous system self-checking, which is blocked in the case of faults.
Available in protectioncategory 2 PL D (IMQ-certified)
Technical features:
- Operating temperature: -20°C, +55°C
- Degree of protection: IP65


Complete the following form to request any type of information
Via Cicogna, 95 San Lazzaro di Savena (Bologna)
from Monday to Friday from 8:30 am to 12:30 am and from 2:00 pm to 6:00 pm
© 2026 AB Tecno S.r.l. - P.IVA IT02329431205 - REA BO430683 - Capitale sociale € 50.000,00 - Via Cicogna 95, S.Lazzaro (Bo) - info@abtecno.com - Privacy e cookie - Developed by LUNA