LZR-P110
Read more
Laser detector for automatic doors
The LZR-P110 laser detector ensures the protection of sliding doors, swing doors and revolving doors in accordance with DIN 18650 and EN 16005 standards.
- Time-of-flight measurement: immune to ground reflectivity
- Free positioning of 2 virtual buttons for opening sliding doors
- Three-dimensional protection at the door threshold and near the closing area with 4 high-resolution laser curtains
- Integrated heating system and snow and rain protection filter (for outdoor use)
Technical features
Maximum detection distance: 5×5 m
Detection mode: presence
Power supply: 10–35 V DC via connector
Output: 2 congurable relays (e.g., slow speed and locking for revolving doors, virtual button and safety mode for sliding doors)
Protection rating: IP65
Operating temperature: -30°C to +60°C under power
Compliance: 2006/95/EC: LVD; 2002/95/EC: RoHS;
2004/108/EC: EMC; 2006/42/EC: MD; EN 12978:2009;
EN ISO 13849-1:2008 CAT2, Pl “d”; EN 60529:2001; IEC
60825-1:2007; EN 60950-1:2005; EN 61000-6-2:2005;
EN 61000-6-3:2006; IEC 61496-1:2009; EN
61496-3:2008 ESPE Type 2; EN 62061:2005 SIL 2; EN
16005:2012 Chapter 4.6.8; DIN 18650-1:2010
Chapter 5.7.4; BS 7036-1:1996 Chapter 8.1
Data Sheet
Instructions Manual

SPK
Read more
Spiral cable
SPK spiral cables are made from high-quality materials, making them suitable for the most intensive installations. The extension factor is four times the block length (BL).
Spiral cables are resistant to microbes, hydrolysis and almost all mineral oils, thanks to a special sheath compound.
In addition, spiral cables are UV-stable and halogen-free.
The material is black PUR/PUR, the colour of the wires complies with DIN 47100:
3 wires = brown, white, green
4 wires = brown, white, green, yellow
5 wires = brown, white, green, yellow, grey
6 wires = brown, white, green, yellow, grey, pink
Variable cable ends (see table), including 40, 50, 60, 80, 100 or 200 mm without sheath and equipped with cable lugs (AEH).
Data sheet

AOS124
Read more
OSE signal converter for LIGI07
The AOS124 signal converter allows a LIGI light curtain with OSE output to be adapted to control panel that do not have this technology.
The OSE signal is converted into a relay signal (potential-free).
Advantages
1 input for 1 OSE device
1 relay output + test input
NO or NC relay output
LED indicators for input and output status
Category 2 device, compliant
with ISO13849-1 standard
Technical specifications
Power supply 19...35 VCC o 19...30 VCA
Input 1x OSE signal
Output Relay/TEST inputs
Light Indicator Yellow LED
Security Cat. 2, ISO 13849-1
Protection degree IP65
Data Sheet

LZR-I100/LZR-I110
Read more
Security sensor for swing and sliding gates and industrial doors
LZR-i100 and LZR-i110 detectors are based on highly accurate time-of-flight technology, ensuring optimal safety at the threshold and in the proximity of the door, with four laser curtains that define corresponding detection areas.
PERFORMANCE
- Adjustable detection area depth (up to 1 m) depending on installation height
- Certified safety solution for industrial doors: PL “d” / CAT 2 according to EN ISO 13849-1 and type E according to EN 12453
- High level of safety with complete three-dimensional detection in front of the door
- Small object detection
APPLICATIONS
- Safety during door opening and closing with 2 separate detection zones
- Possibility to create 2 virtual buttons for door opening
DESIGNED FOR INDUSTRIAL CONTEXTS
- Filters door vibrations and environmental interference
- Filters door frame deformations caused by wind
- Protection rating IP65
Technical features
LZR-i110 - Maximum detection distance: 5 m × 5 m
LZR-i100 - Maximum detection distance: 9.9 m × 9.9 m
Power supply: 10-35V DC on connector
Output: 2 electronic relays (galvanic isolation –
polarity-free)
Maximum switching voltage: 35 VDC / 24 VAC
Maximum switchable current: 80 mA (resistive)
Dimensions: 125 mm (W) × 93 mm (D) × 70 mm (H)
(mounting bracket +14 mm)
Protection rating: IP65
Operating temperature: -30°C to +60°C under power
Compliance: EMC 2014/30/EU; LVD 2014/35/EU; MD
2006/42/EC; ROHS 2 2011/65/EU; EN 12453 chapter
5.1.1.6, chapter 5.5.1 Safety device E; EN 12978; EN ISO
13849-1 Pl ‘d’/ CAT2; EN 60529; IEC 60825-1; EN
60950-1; EN 61000-6-2; EN 61000-6-3; IEC 61496-1; EN
61496-3 ESPE Type2; EN 62061: 2005 SIL 2; DIN 18650-1
Chapter 5.7.4
Data sheet
Instructions Manual